Zolo Technologies, Inc.

For more information visit http://www.zolotech.com.

Navy Lynn F414 Test results

25KHz Temperature measurement

Eight milliseconds of temperature data recorded at 25 kHz (40 microseconds/pt) at an engine exit while in after burner mode. The peak-to-peak variation of the data is 625 K.

 

100KHz Temperature Testing

One second of temperature data recorded at 100 Hz (10 milliseconds/pt) at an engine exit while in after burner mode. Note the repeating patterns of temperature variation.  The peak-to-peak variation of the data is 50 K.

Throttle position ramp testing

Temperature data recorded over about 2 ½ hours at an engine exit location while the throttle position was varied incrementally between low and high power positions. The vertical axis includes 50 degrees per division.

 

Return to Case Studies